6 MANUAL CONTROL
6.1 JOG Operation
419
6
Program example
The program for performing simultaneous start of JOG operations of Axis 1 and Axis 2 is explained as an example.
This program example is explained in the "Q series Motion compatible device assignment" device assignment method.
■
JOG operation conditions
• JOG operation conditions are shown below.
• JOG start command: During X0 ON
■
Motion SFC program
Motion SFC program for which executes the simultaneous start of JOG operation is shown below.
*1 Example of the above Motion SFC program is started using the automatic start or sequence program.
Item
JOG operation conditions
Axis No.
Axis 1
Axis 2
JOG operation speed
150000
150000
JOG operation is executed with the speed of
150000 [mm/min] as the following, when the
2 axes simultaneous start switch (X0) turns on.
Simultaneous start
SET M2042
[F10]
RST M2048
[F30]
[G10]
M2415*M2435
X0
[G20]
D710=H0002
D712=H0001
D640L=K150000
D642L=K150000
SET M2048
[F20]
P1
P1
Turn on all axes servo ON command.
Wait until Axis 1 servo ready and Axis 2 servo ready turn on.
JOG operation is executed at the JOG
operation simultaneous start command ON
Summary of Contents for MELSEC iQ-R16MTCPU