3 PARAMETERS FOR POSITIONING CONTROL
3.11 Vibration Suppression Command Filter Data
211
3
3.11
Vibration Suppression Command Filter Data
Vibration suppression command filter data is for using the vibration suppression command filter.
[Motion Control Parameter]
[Axis Setting Parameter]
"Vibration Suppression Command Filter Data"
*1 Refer to the indirect setting method by devices for parameters for the range of devices used for indirect setting. (
Setting Method by Devices for Parameters)
*2 This setting can be omitted.
No. Item
Default
value
Setting range
Direct
setting
Indirect setting
Reference
Section
mm
inch
degree
pulse
Valid/
invalid
Valid/
invalid
(Required
size)
Fetch
cycle
1
Vibration
suppression
command
filter 1
Mode
selection
device
(1 word)
Operation
cycle
2
Frequency
20 to 25000[
10
-2
Hz]
(1 word)
3
Depth
0:-40dB
1:-24.1dB
2:-18.1dB
3:-14.5dB
4:-12.0dB
5:-10.1dB
6:-8.5dB
7:-7.2dB
8:-6.0dB
9:-5.0dB
10:-4.1dB
11:-3.3dB
12:-2.5dB
13:-1.8dB
14:-1.2dB
15:-0.6dB
(1 word)
4
Vibration
suppression
command
filter 2
Mode
selection
device
(1 word)
5
Frequency
100 to 25000[
10
-2
Hz]
(1 word)
6
Feed current value monitor
device after filter
(2 words)
7
Command output complete
signal after filter
(1 bit)