SAFETY PRECAUTIONS
(Read these precautions before use.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full
attention to safety in order to handle the product correctly.
This manual classifies the safety precautions into two categories: [
WARNING] and [
CAUTION].
Depending on the circumstances, procedures indicated by [
CAUTION] may also cause severe injury.
It is important to follow all precautions for personal safety.
Store this manual in a safe place so that it can be read whenever necessary. Always forward it to the end user.
[DESIGN PRECAUTIONS]
[DESIGN PRECAUTIONS]
WARNING
●
An AnyWireASLINK system has no control function for ensuring safety.
●
Make sure to set up the following safety circuits outside the PLC to ensure safe system operation
even during external power supply problems or PLC failure. Otherwise, malfunctions may cause
serious accidents.
-
Most importantly, set up the following: an emergency stop circuit, a protection circuit, an interlock
circuit for opposite movements (such as normal vs. reverse rotation), and an interlock circuit to
prevent damage (to the equipment at the upper and lower positioning limits).
-
Note that when the CPU module detects an error, such as a watchdog timer error, during self-
diagnosis, all outputs are turned off. Also, when an error that cannot be detected by the CPU
module occurs in an input/output control block, output control may be disabled. External circuits
and mechanisms should be designed to ensure safe machinery operation in such a case.
●
Construct an interlock circuit in the program so that the whole system always operates on the safe
side before executing the control (for data change) of the PLC in operation.
Read the manual thoroughly and ensure complete safety before executing other controls (for program
change, parameter change, forcible output and operation status change) of the PLC in operation.
Otherwise, the machine may be damaged and accidents may occur due to erroneous operations.
●
Especially, when a remote programmable controller is controlled by an external device, immediate
action cannot be taken if a problem occurs in the programmable controller due to a communication
failure. To prevent this, configure an interlock circuit in the program, and determine corrective actions
to be taken between the external device and CPU module in case of a communication failure.
CAUTION
●
Configure safety circuits, such as an emergency stop circuit and interlock circuit, external to the
AnyWireASLINK system.
●
Install module so that excessive force will not be applied to the terminal blocks.
Failure to do so may result in wire damage/breakage or PLC failure.
●
Simultaneously turn on and off the power supplies of the CPU module and extension modules.
WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in
death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in
minor or moderate injury or property damage.
Summary of Contents for MELSEC iQ-F FX55-ASL-M
Page 1: ...MELSEC iQ F FX5 User s Manual ASLINK ...
Page 2: ......
Page 12: ...10 INDEX 88 REVISIONS 90 WARRANTY 91 TRADEMARKS 92 ...
Page 13: ...11 CONTENTS ...
Page 23: ...3 PROCEDURES BEFORE OPERATION 21 3 MEMO ...
Page 91: ...I 89 MEMO ...
Page 95: ......