6 SEQUENCE INSTRUCTIONS
6.6 Termination Instructions
163
6
Operation error
Error code
(SD0/SD8067)
Remarks
3340H
The END instruction is executed before the NEXT instruction after the FOR instruction is executed.
3381H
The END instruction is executed before the RET instruction after the CALL(P) instruction is executed.
33E3H
The END instruction is programmed between FOR-NEXT.
33E4H
The END instruction is programmed between MC-MCR.
33E5H
The END instruction is programmed between STL-RETSTL.
33E7H
The END instruction is programmed between I-IRET.