The following table lists the types of data that can be used for instructions in CPU modules.
Device data
*1 A constant can be used in the data specified for the source (s) or numerical data (n) by an instruction.
*2 For the specification method, refer to the detail page of each data type.
Data
Classification
Bit data
Bit data
16-bit data (word data)
16-bit signed binary data
16-bit unsigned binary data
32-bit data (double-word data)
32-bit signed binary data
32-bit unsigned binary data
Real number data (floating-point data)
Single-precision real number data
BCD data
BCD 4-digit data
BCD 8-digit data
String data
String
Data type
Description
Specifiable device/constant
Bit
Bit data can be handled.
• Bit device
• Bit specification of word device
Word
Word data can be handled.
Page 29 16-bit data (word data)
• Word device
• Nibble specification of bit devices (K1 to
K4)
• Decimal constant
• Hexadecimal constant
16-bit signed binary
16-bit data can be handled.
The value range varies depending on whether the value is signed or unsigned.
Page 29 16-bit data (word data)
16-bit unsigned binary
Double word
Double-word data can be handled.
Page 31 32-bit data (double word data)
• Word device
• Double-word device
• Nibble specification of bit devices (K1 to
K8)
• Decimal constant
• Hexadecimal constant
32-bit signed binary
Two consecutive sets of 32-bit data or 16-bit data can be handled.
The value range varies depending on whether the value is signed or unsigned.
Page 31 32-bit data (double word data)
32-bit unsigned binary
BCD 4-digit
BCD 4-digit data can be handled.
16-bit data is divided by 4 digits and each digit is specified in 0 to 9.
• Word device
• Nibble specification of bit devices (K1 to
K4)
• Decimal constant
• Hexadecimal constant
BCD 8-digit
BCD 8-digit data can be handled.
32-bit data is divided by 8 digits and each digit is specified in 0 to 9.
• Word device
• Double-word device
• Nibble specification of bit devices (K1 to
K8)
• Decimal constant
• Hexadecimal constant
Single-precision real
number
Single-precision real number data (single-precision floating-point data) can be
handled.
Page 34 Configuration of single-precision real number data
• Word device
• Double-word device
• Real constant
Character string
ASCII code and Shift JIS code character string data can be handled.
• Word device
• Character string constant
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......