562
8 APPLICATION INSTRUCTION
8.12 Data Control Instruction
Zone control of 32-bit binary data
DZONE(P)(_U)
These instructions add the bias value specified by (s1) or (s2) to the input value specified by (s3), and store the operation
result in the device specified by (d).
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
Ladder diagram
Structured text
ENO:=DZONE(EN,s1,s2,s3,d);
ENO:=DZONEP(EN,s1,s2,s3,d);
ENO:=DZONE_U(EN,s1,s2,s3,d);
ENO:=DZONEP_U(EN,s1,s2,s3,d);
FBD/LD
Operand
Description
Range
Data type
Data type (label)
(s1)
DZONE(P)
Negative bias value to be added to the input
value
-2147483648 to +2147483647
32-bit signed binary
ANY32_S
DZONE(P)_U
0 to 4294967295
32-bit unsigned binary
ANY32_U
(s2)
DZONE(P)
Positive bias value to be added to the input value
-2147483648 to +2147483647
32-bit signed binary
ANY32_S
DZONE(P)_U
0 to 4294967295
32-bit unsigned binary
ANY32_U
(s3)
DZONE(P)
Input value for performing the zone control
-2147483648 to +2147483647
32-bit signed binary
ANY32_S
DZONE(P)_U
0 to 4294967295
32-bit unsigned binary
ANY32_U
(d)
DZONE(P)
Head device number storing the output value
controlled by the zone
32-bit signed binary
ANY32_S
DZONE(P)_U
32-bit unsigned binary
ANY32_U
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
X, Y, M, L, SM,
F, B, SB, S
T, ST, C, D, W,
SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s1)
(s2)
(s3)
(d)
(s1)
(s2)
(s3)
(d)
EN
ENO
d
s1
s2
s3
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......