3. POSITIONING SIGNALS
3
−
51
REMARKS
1)
The travel value per manual pulse generator pulse is set in one of the
following units.
•
Setting unit
mm
: 0.1
µ
m
inch
: 0.00001 inch
degree : 0.00001 degree
PULSE : 1 PLS
2)
The range for the smoothing time constant is 56.8 ms to 3408 ms.
(10) PC link communication error code (D9196)
When an error occurs during PC link communication, the error code that
corresponds to the error is stored in this device.
PC Communication Error Code
Storage Register
Contents
D9196
00: No error
01: Receiving timing error
02: CRC error
03: Communication response code error
04: Receiving flame error
05: Communication task start error
(Each error code is reset to 00 when
normal communication is restarted.)
For details of PC link communication errors, see Appendix 2.5.