6. SERVO PROGRAMS FOR POSITIONING CONTROL
6
−
8
Settings Made Using the Sequence Program (Indirect Setting)
Indirect Setting
Processing in Event of Setting Error
Setting Range
mm
inch
degree
PULSE
Possible/Not
Possible
Number of
Words Used
Error Item
Data
(Note-4)
(Stored in D9190)
Control Using
Default Value
Starting not
Possible
1 to 16
"
1
1
"
×
−
2147483648
to 2147483647
(
×
10
−
1
µ
m)
−
2147483648
to 2147483647
(
×
10
−
5
inch)
0 to 35999999
(
×
10
−
5
degree)
−
2147483648
to 2147483647
For other than speed/position switching control
0 to
±
2147483647
n03
(Note-1)
For speed/position switching control
0 to 2147483647
(
×
10
−
1
µ
m)
0 to 2147483647
(
×
10
−
5
inch)
0 to 2147483647
(
×
10
−
5
degree)
0 to 2147483647
"
2
"
1 to 600000000
(
×
10
−
2
mm/min)
1 to 600000000
(
×
10
−
3
inch/min)
1 to 2147483647
(
×
10
−
3
degree/min)
1 to 10000000
(PLS/s)
"
2
4
"
(note-2)
"
(Note-3)
0 to 5000 (ms)
"
1
5
"
0 to 255
"
1
6
"
1 to 500 (%)
"
1
7
"
−
2147483648
to 2147483647
(
×
10
−
1
µ
m)
−
2147483648
to 2147483647
(
×
10
−
5
inch)
0 to 35999999
(
×
10
−
5
degree)
−
2147483648
to 2147483647
0 to
±
2147483647
"
2
×
2
n08
(note-1)
1 to 4294967295
(
×
10
−
1
µ
m)
1 to 4294967295
(
×
10
−
5
inch)
0 to 35999999
(
×
10
−
5
degree)
1 to 4294967295
1 to 2147483647
(
×
10
−
1
µ
m)
1 to 2147483647
(
×
10
−
5
inch)
1 to 2147483647
(
×
10
−
5
degree)
1 to 2147483647
"
2
n09
(Note-1)
"
−
2147483648
to 2147483647
(
×
10
−
1
µ
m)
−
2147483648
to 2147483647
(
×
10
−
5
inch)
0 to 35999999
(
×
10
−
5
degree)
−
2147483648
to 2147483647
0 to
±
2147483647
"
2
×
2
n010
(Note-1)
0 to 999
"
1
28
REMARKS
(Note-1): The "n" in n03, n08, n09, n10, indicates the axis number (1 to 4/1 to 8/1).
(Note-2): When an error occurs because the speed limit value is exceeded, control
is executed at the speed limit value.
(Note-3): Applies when the commanded speed is "0".
(Note-4): If there are multiple errors in the same program, the latest error item data
is stored.