7. POSITIONING CONTROL
7
−
30
(4) Operation timing
The operation timing for 3-axes linear interpolation control is shown below.
V
PLC ready (M2000)
All axes servo start command
(M2042)
All-axis servo start accept flag
(M2009)
Positioning start command (X000)
SVST instruction
Axis 1 start accept flag (M2001)
Axis 2 start accept flag (M2002)
Servo program No. 21
Axis 3 start accept flag (M2003)
(5) Servo program
The servo program No. 21 for 3-axes linear interpolation control is shown below.
3-axes linear interpolation control
Axis used
Axis
1,
Axis
2,
Axis
3
Positioning address
Commanded positioning speed
Combined speed
1000
<K
21>
ABS -3
Axis
1,
50000
Axis
2,
40000
Axis
3,
30000
Combined speed
1000
Axis
1
50000
Axis
2
40000
Axis
3
30000
Downloaded from