1. GENERAL DESCRIPTION
1
−
5
POINT
1. When using the existing A171SCPU user program and parameters,
perform the following procedure:
(1) Start the programming S/W package by A172SHCPUN or
A171SHCPUN, then read the sequence file and servo file created for
A171SCPU via the File Read function.
↓
(2) Display the System Setup screen.
The existing system status is displayed with the following alert:
(Start by A172SHCPUN)
Replaces A171SCPU with A172SHCPUN........ The character string “A171SHCPUN” is
displayed only when A171SHCPUN is
used for startup.
Replaces A171SENC with A172SENC. ...... This message is displayed only when
A171ENC has been set.
↓
(3) Select “YES” and the existing settings will be replaced with those for
the startup CPU module.
Select “NO” and the existing A171SCPU settings will remain in effect.
(Note): Other than system setup data can be used without change.