7. POSITIONING CONTROL
7
−
13
(c) Stop commands and stop causes
Some stop commands and stop causes affect individual axes and others
affect all axes.
However, during interpolation control, stop commands and stop causes
which affect individual axes also stop the interpolation axes.
For example, both Axis 1 and Axis 2 stop after input of a stop command or
stop cause during interpolation control of Axis 1 and Axis 2.
Stop
No.
Stop Cause
Individual/
All Axes
Positioning
Control
Speed
Control
Jog
Operation
Zeroing
Manual
Pulse
Generator
Error Processing
1
External STOP input ON
Process 1 or Process 2
According to deceleration processing on
STOP input parameter in parameter block.
2
Stop command
M1800
+
20n/Yn0/M3200
+
20n ON
Process 1
3
Rapid stop command
M1800
+
20n/Yn1/M3201
+
20n ON
Process 2
4
External FLS input OFF
5
External RLS input OFF
Process 1 or Process 2
According to deceleration processing on
STOP input parameter in parameter block.
6
Servo error detect
M1608
+
20n/Xn8/M2408
+
20n ON
Individual
Process 3
7
PLC ready M2000 OFF
Process 1
8
Emergency stop from
exterior
(Note-2)
, BREAK
key pressed
Process 2
9
Servo system CPU stop
Process 1
Serious error during
zeroing only
10
Servo system reset
Process 3
(Note-1)
11
PCPU WDT error
Process 3
(Note-1)
M9073 (WDT error) ON
12
SCPU WDT error
Process 1
13
Servo system CPU
power off
All
Process 3
(Note-1)
14
Servo amplifier power off
Individual
Process 3
(Note-1)
Process 3
Serious error at start-up
(no servo)
15
Speed changed to zero
Individual
(Note
-3)
Process 1
(Note-1): Emergency stop due to H/W
(Note-2): Test mode
(Note-3): Applies to all axes set to speed = 0 in servo program.