Appendix 6 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
App
- 29
17
ADDI
TIO
N
TIMES
RE
SET FOR
MA
INTENA
N
C
E
18
INST
ALL
A
TI
ON OF
B
O
OT
O
S
A
ND
ST
A
N
DA
RD OS
19
MAIN
TE
NANCE A
ND
INSP
ECTIO
N
20
ERROR MESS
AGE
AND SYSTE
M
ALA
R
M
AP
PENDI
C
E
S
IND
E
X
(Continued to next page)
Item
Description
Version of GT
Designer2
Version of OS
GT
15
GT Soft
GOT1000
GT
11
Station No.
Switching Function
Designation of the channel No. for which
station No. is switched is possible.
2.18U
Standard monitor OS [02.02.**]
Language
Switching Device
Language switching device can be used.
2.00A
Standard monitor OS [01.00.**]
2.18U
Standard monitor OS [02.02.**]
Password Setting
Password can be set for the connection of
motion controller and servo amplifier.
2.18U
Standard monitor OS [02.02.**]
System
information
System information of report function and
print are added.
2.27D
Standard monitor OS [02.04.**]
D drive automatic recovery status
notification signal is added.
2.32J
Standard monitor OS [03.00.**]
System information regarding B drive has
been added.
2.43V
Standard monitor OS [03.01.**]
Security
The name [Password] is changed to
[Security] in the system environment.
2.58L
Standard monitor OS [03.03.**]
Enables setting the operator
authentication.
2.58L
Extended function OS
Operator authentication [03.03.**]
GOT Setup
In clock management, both adjust and
broadcast can be set.
2.18U
Standard monitor OS [02.02.**]
Data save device of MELSEC-Q / QnA
ladder monitor data can be set at GT
Designer2.
2.18U
-
Automatic program read at the start of
ladder monitor for MELSEC-Q/QnA/
Priority Level Comment can be set.
2.43V
-
Time setting for call key ON until the start
up of utility can be set (for 1-point
pressing).
2.18U
Standard monitor OS [02.02.**]
Alarm can be set to be displayed in
system language switching or battery
drops.
2.27D
Standard monitor OS [02.04.**]
Enables the backup/restore setting.
2.58L
-
Enables the setting for monitoring local
devices.
Enables setting the drive for collectively
reading comment data.
Clock Setting
Designation of the channel No. used for
adjusting and broadcasting is possible.
2.18U
Standard monitor OS [02.02.**]
Startup Logo
Function for setting any screen for the
GOT startup screen
2.09K
Standard monitor OS [01.02.**]
Boot OS [01.02.**.C]
Handy GOT
Setting
Setting of the grip switch LED of handy
GOT
2.18U
Standard monitor OS [02.02.**]
Dialog window
System messages to be displayed on
GOT can be customized or created by the
user.
2.27D
Standard monitor OS [02.04.**]