11
- 3
11.1 Display Settings
11.1.1 Display setting functions
*1: If setting 0, the title screen is not hidden.
The title screen is always displayed for 4 seconds or longer (which changes depending on the project data
contents).
*2: The monitoring time corresponding to the sensor detect level (0 to 10) is as follows.
As the sensor detect level becomes greater, the sensitivity of the human sensor becomes higher.
*3: Only selectable languages are displayed.
The selectable languages differ depending on the fonts installed in the GOT.
For details of the fonts, refer to the following manual.
GT Designer2 Version Screen Design Manual (2.3 Specifications of Applicable Characters)
(1) Display setting by GT Designer2
Set title display period, screen save time and screen save backlight at [GOT set
up] in [System Environment] of GT Designer2.
When change a part of the setting after downloading the project data, change the
setting by [Display] screen of the GOT.
GT Designer2 Version
Screen Design Manual
(3.8 Setting of the GOT display and operation (GOT setup) )
(2) Screen save time
Using the system information function can compulsorily switch the controller to the
screen saving status (Forced Screen Saver Disable Signal) or disable the screen
save time (Automatic Screen Saver Disable Signal) set with Utility.
GT Designer2 Version
Screen Design Manual
(3.6 Setting System Information)
(3) Screen save backlight
When [Screen save backlight] is set to [ON], using the system information function
(Backlight OFF output signal) can switch the backlight OFF from the controller.
When [Screen save backlight] is set to [OFF], the above signal has no effect on
the screen save backlight.
GT Designer2 Version
Screen Design Manual
(3.6 Setting System Information)
Sensor detect time
*2
The time corresponding to the [Sensor detect
level] is displayed. (setting is disabled)
When the [Sensor detect level] is changed, the
corresponding time is reflected by touching
button.
0 to 4
<At factory shipment: 4sec>
Sensor off delay
The time period from when the human sensor
detects no human movement until the Human
Sensor Detection Signal (System Signal 2-1.b5)
turns OFF can be set.
0Min 10Sec to 60Min 0Sec
<At factory shipment: 0Min
10Sec>
Sensor detect level
10
9
8
7
6
5
4
3
2
1
0
Monitoring time [s]
0
0.1
0.2
0.4
0.8
1
1.5
2
2.5
3
4
Items
Description
Setting range
Enter