Technician’s Handbook
74
Test/Verify (Ground Start)
Verify the far-end (CO) circuits by using a standard telephone for
incoming calls. Verify outgoing calls by using a Butt Set with a ground-
start lead (momentarily shorting the ring lead to the ground will produce
a dial tone from the far end).
Verify the near-end (PBX Ground Start) circuits by connecting to known
working far end Ground Start circuits.
Verify that appropriate voltages are present on Tip-Ring in each call
state.
During off-hook condition, 18 mA DC minimum should be drawn from
the CO (typical 35-40 mA).
Tip-Ring is polarity sensitive. PBX will be unable to initiate calls if
reversed. Reverse polarity to verify.
Stop Dial
-
-
Receipt of Digits
Audible Tones - Busy,
Reorder, Ringback dependent
upon digits dialed and called
party condition
-
Answer
Supervision
CO reverses current flow in
Tip-Ring
Disconnect
Supervision
Near-end: PBX opens loop
Far-end: CO removes ground
from ring
Near or Far-end
termination: Loop
Current is broken
Table 7: Ground Start Trunk Summary (Continued)
Signal
Ground Start Trunk PBX
Outgoing
Ground Start Trunk
PBX Incoming
(Sheet 2 of 2)
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...