Technician’s Handbook
80
Test/Verify (E&M)
Loop back to self whenever more than 1 E&M type V circuit is available.
Verify far-end circuits by activating near-end M lead and listening for far-
end dial tone.
Verify near-end circuits by activating near-end E lead and listening for
near-end dial tone.
Verify that appropriate voltages are present on E&M leads in each call
state.
Digits
M toggles (Rotary) or DTMF
through audio path
E toggles (Rotary) or DTMF
through audio path
Stop Dial
E lead goes active; goes
inactive when ready to go
-
Receipt of Digits
Audible Tones - Busy,
Reorder, Ringback
dependent upon digits
dialed and called party
condition
Audible Tones - Busy,
Reorder, Ringback
generated and sent to
calling party dependent
upon digits received and
called party condition
Answer
Supervision
E lead goes active
M lead goes active
Disconnect
Supervision
Near-end termination: M
lead goes inactive; E follows
Far-end termination: E lead
goes inactive; M follows
Near-end termination: M
lead goes inactive; E follows
Far-end termination: E lead
goes inactive; M follows
Table 9: E&M Trunk Summary (Continued)
Signal
E&M Trunk PBX
Outgoing
E&M Trunk PBX
Incoming
(Sheet 2 of 2)
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...