Technician’s Handbook
120
5. Form 16, Trunk Groups
n
Assign to a trunk group if outgoing.
Programming a range of Dial-in Trunks
The RANGE PRGRM softkey allows block programming of trunks on
the same card. You must program the first trunk in the range and then
press RANGE PRGM to copy the values to the range of trunks that you
specify. The following fields are copied from the first trunk in the range:
n
COS, COR, TEN, N1, M, X, CDN
The TK NAME and COMMENTS fields are left blank.
The trunk numbers are assigned in sequence, beginning with the first
trunk in the range. If there are trunks that are already programmed
within that range, those trunks are skipped. The trunk number sequence
is incremented each time a trunk is skipped. If the trunk number is
incremented to a value that is already used, the sequence continues to
increment until a free number is found. The trunk numbers restart at 1
if necessary. An error message is displayed if there are no more free
trunk numbers.
NOTE:
BRI trunks are not supported.
To program a range of trunks:
1. Program the first trunk in the range. Enter values for the COS, COR,
TEN, N1, M, X, CDN fields.
2. Press RANGE PRGRM.
The system displays: FROM BAY: SLOT: CIRCUIT:.
CDE Form 15 does not accept trunk programming changes if
the T1 card or T1/E1 module is installed and the T1 link is down
but active. To make a programming change for a T1 card,
unplug the T1 card, make the programming change and then
re-insert the T1 card . To make a programming change for a
T1/E1 module, insert a Peripheral Interface Card (PIC) into the
software location (slots 5 or 6) for that T1 link, make the
programming change, and then remove the PIC from the slot to
reset the T1 link.
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...