Technician’s Handbook
30
To change the block check type
1. Select SYSTEM from the Maintenance screen:
2. Select the following softkeys:
DATABASE
SET_PARAM
BLOCK_CHECK
ENTER
3. Enter the Block Check (03) and select CONFIRM.
The screen confirms your setting with a display of the Kermit
Receive Parameters and the Kermit Send Parameters.
Downloading the Remote Software
Downloading LIGHTWARE 19 software for the BCC III and the MCC
with a 4 Meg Flash card requires a two step procedure. You download
the software for the MCC first and then download the software for the
BCC III. Because the system only accepts software that is compatible,
the system will inform you of the status of the software during the
download process.
1. Back up the database.
2. Load the new operating software from the PC.
Select the following commands from SYSTEM maintenance:
DATABASE
SW_RESTORE
ENTER
3. Select CONFIRM if you agree with the terms stated in the window.
Note that upgrading software for the BCC III with a 4 Meg Flash
card always requires you to download the software for the main
control card first.
Refer to
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...