Troubleshooting and Repair
71
Tr
oub
le
sho
oting
Loop Start Line/Trunk
The Loop Start Line/Trunk serves the standard domestic applications
and small businesses that have key systems and PBX applications.
Figure 13: Loop Start Line/Trunk
Table 6: Loop Start Line/Trunk Summary
Signal
Loop Start Line PBX
Outgoing
Loop Start Line PBX
Incoming
Seize
Tip-Ring leads activated
(shorted); Loop Current flows
in line
90Vac is applied to Ring
lead in 2 sec on, 4 sec
off cadence
Seize
Acknowledgment
Loop Current and/or dial tone
generated
-
Digits
Loop Current toggled (Rotary)
or DTMF
-
Stop Dial
-
-
(Sheet 1 of 2)