Technician’s Handbook
64
6. The resistance between the two grounds should be less than five
OHMS. If not, try alternate ground point(s) and repeat the test.
Testing the CO and PBX Ground Differential
If a PBX experiences trunk lock-ups, or trunk seize failures, perform the
CO/PBX Ground Differential Test.
This test determines whether the DC ground potential between the
selected building ground point and the CO ground point is within
acceptable limits by measuring the two currents: “Loop” current and
“Ring” current.
Divide the measured “Ring” current by the measured “Loop” current to
determine the relation of the building ground potential to the CO ground
potential. The result is 2.0 if the CO and PBX ground points are the
same potential.
A result between 1.85 and 2.15 indicates an acceptable building
ground. A result outside these limits means that you must locate an
alternate building ground.
1. Disconnect the building ground wire from the PBX ground-stud.
2. Disconnect a loop-start or ground-start trunk from the PBX.
3. Measure the Loop current.
n
Set the meter to Milliamperes = DC and Range = 200
Milliamperes.
n
Connect the meter between the Tip and Ring trunk leads.
n
For a ground-start trunk, apply the building ground momentarily
to the ring side of the trunk. This application of ground will signal
the CO to complete the loop and provide DC loop current.
n
Allow sufficient time for the current to stabilize and record the
loop current.
n
DC Loop Current = _______________________
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...