![MIOX RIO-S Series Installation, Operation And Maintenance Manual Download Page 13](http://html1.mh-extra.com/html/miox/rio-s-series/rio-s-series_installation-operation-and-maintenance-manual_1804803013.webp)
MIOX RIO-S Series Operators Manual
102-00130-D
Page
13
Installation Preparation
Your RIO-S OSG has been factory tested and must be properly installed by technicians
trained by MIOX or its representatives. This chapter describes the procedures for unpacking
and installing the RIO-S OSG and auxiliary equipment, including all requirements for
plumbing and electrical tie-ins. Specifications and conditions regarding electrical power to
the unit, water quality, water line pressure requirements, and other requirements for
installation of your OSG are discussed.
SAFETY PRECAUTIONS AND WARNINGS
Ensure that the facility and the installation are in conformance with all codes
and standards.
Please refer to the MIOX Hydrogen Safety White Paper or your local authority
having jurisdiction for more information.
Untrained persons should not
attempt to install or operate MIOX OSGs.
A liquid barrier system is mandatory. Ensure that all hydrogen vent lines
slope towards the oxidant tank.
Ensure that no valves, drop legs, or P-traps are in the hydrogen vent lines.
Do NOT cross connect vent lines.
Ensure that brine and oxidant tanks are labeled properly.
Disconnect power before working on the system. Do not reconnect the power
to switch gear enclosure until installation is complete.
All MIOX systems require a good earth ground. A neutral is not a substitute
for a proper earth ground. Electrical wiring to all MIOX systems should be
performed by a certified electrician. The circuit feeding the MIOX OSG should
be separated from other power devices.
Failure to install unit properly can result in electrical shock.
Standard packing list
1.
RIO-S OSG
2.
RIO-S Installation, Operation, and Maintenance Manual
3.
Documentation Kit
4.
Brine Tank (if ordered)
5.
Oxidant Storage Tank with Hydrogen Vent Kit (if ordered)
6.
2” 3-way oxidant sampling valve
7.
2” Oxidant Check Valve
Safety