Pellerin Milnor Corporation
73
1. Reconfigure the machine according to the configuration infor-
mation in
.
2. Reinstall the standard (default) formulas according to the de-
fault formula loading procedure in
3. Reprogram any lost wash formulas according to
.
MEMORY: FLASH IS NOT
This message appears when the microprocessor cannot read from
the flash memory.
TALKING
1. Lock off and tag out power to the machine.
2. Replace flash memory. Contact the Milnor
®
factory to ensure
that the replacement memory is the most current version for
your machine.
3. Restore power to machine.
4. Reconfigure the machine according to the configuration infor-
mation in
.
5. Reinstall the standard (default) formulas according to the de-
fault formula loading procedure in
.
6. Reprogram lost wash formulas according to
A/D BOARD IS
This error message indicates that the analog to digital board is not
communicating with the microprocessor.
NOT TALKING
1. Lock off and tag out power to the machine.
2. Check the connections at both ends of the ribbon cable be-
tween the processor board and the analog to digital board.
3. Restore power.
4. If the error persists, lock off and tag out power to the machine.
Have a qualified service technician replace the suspect board.
4.2.2
Error Messages during Normal Operation
BNCJHT02.R01 0000192187 C.2 B.3 1/2/20 1:16 PM Released
If an error message appears on the bottom line of the display while the machine is running, the
timer shown on the top line will stop counting. When the error is corrected, the timer resumes
Summary of Contents for E-P Plus
Page 2: ......