Display or Action
Explanation
PRESS START TO RUN
On most machine models, this display appears when power is re-
stored. The formula and step which were in progress when power
was interrupted are shown.
STEP xx - FORMULA yy
Resumes the formula at the displayed formula and step. If the out-
age occurred in a bath step, level and temperature (if commanded)
must again be satisfied, even if these were already satisfied before
power was lost. Any commanded chemicals will be injected
again.
If the outage occurred during a drain, that step will be repeated,
then followed by the next commanded step.
If the outage occurred during an extract step, the previous bath
will be repeated before the extract step begins.
Terminates the formula in progress.
3.1.7
How the Flush Valve Works
BNCJHO01.C09 0000182500 C.2 B.3 A.3 1/2/20 1:16 PM Released
The E-P Plus controller provides an output signal that activates the flush valve for 20 to 30 sec-
onds after the last chemical has been injected into each bath. If a bath is shortened or terminated
before or while this valve is energized, the flush valve will be turned off. Shortening or terminat-
ing a bath may prevent the flush valve from activating.
NOTE:
On 48040F__ models, the chemical flush is pulsed two times for 10 seconds,
with 10 seconds between pulses. If hot water is required to restore level while the flush
valve is open, the flush valve closes and the flush timer halts until the hot water output
turns off.
3.1.8
How Cooldown Works
BNCJHO01.C10 0000182521 C.2 B.3 A.3 1/2/20 1:16 PM Released
Goods must be cool enough to handle immediately after a wash cycle is finished. However, a
drastic temperature change may set wrinkles in goods of certain fabrics. Therefore, many Milnor
washer extractors employ a feature called cooldown to gradually lower the water temperature and
thus provide cool goods at the end of the wash cycle without setting wrinkles.
For F_J, H_J, V_J, and X_J models, the cooldown valve is turned on until high (cooldown) level
is reached. This causes the drain to open and the cooldown valve to close until high level is lost.
When high level is lost, the drain closes and the cooldown valve opens. This process continues
until the cooldown step is complete.