4.1.5
Testing and Verifying the DIP Switch Settings
BNCJHT01.C04 0000191866 C.2 F.3 C.3 1/2/20 1:16 PM Released
For all E-P Plus models, the set of default formulas is determined by how the DIP switches on the
processor board are set. The bank of DIP switches is identified in
Figure 9: Processor Board, page
.
Figure 9.
Processor Board
Photograph of Typical Processor Board
Legend
A...
Display connectors
B...
Switch panel connector
C...
DIP switches
D...
Temperature probe connector (E-P Plus
models only)
E...
Pressure transducer for level (E-P Plus mod-
els only)
F...
Capacitor to retain memory
G...
Outputs to chemical pumps
H...
Standard outputs
I...
Operator signal buzzer
J...
CPU chip
K...
Input connector
There is one unique number which identifies each possible combination of on/off settings at the
DIP switch. While the industry configuration (switch 1 through switch 4) is readily available
from the
Software version mode
(described in
4.1.2: Determining the Software Version, page 62
), the settings of other switch positions are only apparent from this display or by looking at the
processor board.
Display or Action
Explanation
Enters the
Manual menu
from the
Run mode
.
MANUAL MENU
This is the first item of the
Manual menu
.
1
SOFTWARE DATE CODE
,
Scrolls down to the
Test DIP Switch
item.
MANUAL MENU
This is the
Test DIP Switch
item of the
Manual menu
.
4
TEST DIP SWITCH
Accesses the
Test DIP Switch
function and displays the DIP
switch setting.
This is an example of the DIP switch display. Referencing this
number in
shows that the sample machine is configured for Correc-
tional Laundries, and that switch position 5 is OFF and 6 is ON.
208
Terminates the
Manual menu
and returns controller to
Run
mode
.