Pellerin Milnor Corporation
63
4.1.3
Viewing Microprocessor Inputs
BNCJHT01.R04 0000190747 C.2 F.3 B.3 1/2/20 1:16 PM Released
The on/off state of each input to the microprocessor can be displayed by using the
Test Inputs
se-
lection of the
Manual menu
. The machine must be idle (not running a formula).
Display or Action
Explanation
Accesses the
Manual menu
.
MANUAL MENU
2
TEST INPUTS
Manual menu
accessed and
Test Inputs
mode selected.
Accesses the
Test Inputs
mode.
ABCDEFGHIJKLMNOP (-)
+--++----+----+- OFF
The input display code on the top row corresponds to a display
code in the table of inputs in this section. The status of the input is
displayed beneath each code. If the input is grounded, a “+” ap-
pears. Non-grounded inputs are represented by “–”.
Restores the controller to the
Run mode
.
RUN FORMULA
00
OK TO POWER OFF
This is the
Run mode
display. Select a formula to run, or shut
down the machine.
Table 12.
E-P Plus Inputs
Display Code
Input Name
Connector-Pin
A
Door closed
M6–1
B
not used
M6–9
C
Vibration switch tripped
M6–2
D
Input from Inverter
M6–10
E
not used
M6–3
F
Keyswitch in Program position
M6–11
G
not used except in 48040F7J/B
M6–4
Brake is OFF (48040F7J/B only)
H
Halt—external fault
M6–12
Bearing pressurized (48040F7J/B only)
I
Halt—bath time
M6–5
J
Front not down (48040F7J/B only)
M6–13
K
not used
M6–6
L
not used
M6–14
M
not used
M6–7
N
not used
M6–15
O
not used
M6–8
P
not used
M6–16