64
Pellerin Milnor Corporation
4.1.4
Actuating Microprocessor Outputs
BNCJHT01.R05 0000190746 C.2 F.3 B.3 1/2/20 1:16 PM Released
Machine functions may be tested individually or in groups by using the
Test Outputs
component
of the
Manual menu
. The machine must be idle (not running a formula).
DANGER:
Crushing and Entanglement Hazard —
Bare manual outputs actuate
washer-extractor mechanisms. Keep all personnel clear.
Display or Action
Explanation
Accesses the
Manual menu
.
MANUAL MENU
3
TEST OUTPUTS
This is the
Manual menu
display with the
Test Outputs
compo-
nent selected.
Accesses the output testing selection.
TEST OUTPUTS
01
INJECT CHEMICAL 5
This is the
Output testing
display.
Indexes forward and backward through the output names, as
shown in the table of outputs in this section.
TEST OUTPUTS
07
COLD WATER VALVE
Example display with output in place to be selected and subse-
quently actuated.
Accesses the selected output for actuation. All outputs are initially
disabled when accessed.
COLD WATER VALVE
0=OFF
1=ON
0
Example display with output accessed and disabled.
Enables the output (turns the output on).
COLD WATER VALVE
0=OFF
1=ON
1
Example display with output enabled. The cold water valve is
open.
If the output was already on, this keystroke turns it off.
COLD WATER VALVE
0=OFF
1=ON
0
Example display with output disabled. The cold water valve is
closed.
Disables (turns off) the output if it was previously enabled, and
advances to the next output.
HOT WATER VALVE
0=OFF
1=ON
0
Display after pressing
to advance to the next output.
Disables the output if it was enabled, then returns to the
Run
mode
.
RUN FORMULA
00
OK TO POWER OFF
Display of
Run mode.
Summary of Contents for E-P Plus