40
Pellerin Milnor Corporation
Display or Action
Explanation
RUN KEY TURNED EARLY
ALL NEW CHANGES LOST
This message appears on later software versions only. It indicates
that the key was turned to
before
was pressed.
Returns the controller to the
Program menu.
PROGRAM
0
MENU
OK TURN KEY TO RUN
This is the
Program menu
, from which the operator can correctly
save the modified formulas.
,
Saves all formula modifications and returns the controller to the
Run mode
.
PLEASE WAIT
This display indicates that the formula modifications are being
saved in permanent memory.
RUN FORMULA
00
OK TO POWER OFF
This is the
Run Formula
display.
2.3.3.6.8
How to Save or Discard Changes
BNCJUP03.C20 0000192000 C.2 D.2 A.8 1/2/20 1:16 PM Released
Use the procedures detailed above to navigate in a formula and make changes. The following pro-
cedures should be used to return to the formula menu and either save or discard the changes
made.
Display or Action
Explanation
Saves all changes if the cursor is on the
Step Number
. This key
may need to be pressed more than one time to exit the formula.
Exits the formula and discards all changes made during this pro-
gramming session.
2.3.4
Configure the Control (Option 2)
BNCJUP04.C01 0000192159 C.2 D.2 B.3 1/2/20 1:16 PM Released
Because the microprocessor control system used in this machine is capable of controlling several
different models with a wide variety of options, each unit must be configured to match its specific
model and type of washer-extractor. This configuration informs the microprocessor of the charac-
teristics of this machine, such as the number of water valves, the presence of temperature control,
cooldown, etc. Such decisions are discrete to the specific machine and must never be changed un-
less options are later added or removed. In addition to these hardware-specific decisions, certain
configuration choices, such as the display of English or metric units, are left to the discretion of
the owner/operator.
TIP:
The Milnor
®
E-P Plus
®
Programmer software for Microsoft Windows allows the
user to configure the machine and program formulas on a personal computer, then down-
load the data to each machine through a special cable (Milnor part number
KXMDSWBRS1). With the E-P Plus Programmer, descriptive names for each formula
can be created and downloaded. When a machine is configured by using the front panel
controls instead of the programmer software, all descriptive formula names will be re-
placed with “Formula XX,” where XX is the formula number.