28
Pellerin Milnor Corporation
the machine enters an extract step from a bath step. Also, add 1:00 for each standard drain (drain
speed), or 1:00 for each two-way wash drain.
Display or Action
Explanation
03 TMMQ
FFF
HC LSCWSS*
01
XXX
Temperature decision appears only if the machine is supplied with
and configured for temperature control (
Temp Control = Yes
).
Detailed configure instructions are provided elsewhere in the
manual. See the table of contents.
— — —
Display if no temperature is commanded. The cursor skips to the
next decision.
050°F / 010°C
Minimum temperature in any bath
205°F / 095°C
Maximum temperature in any bath
03 TMMQFFF
H
C LSCWSS*
01
X
Control of hot water valve
0
Hot water valve off
1
Hot water valve on
2
Raises temperature of filling water. See
ulate Water Valves to Regulate Incoming Water Temperature,
page 29
for more information.
3
invalid response—not allowed
03 TMMQFFFH
C
LSCWSS*
01
X
Control of cold water valve
0
Cold water valve off
1
Cold water valve on
2
invalid response—not allowed
3
Lowers temperature of filling water. See
ulate Water Valves to Regulate Incoming Water Temperature,
page 29
for more information.
03 TMMQFFFHC
3
LSCWSS*
01
X
Third water only appears if machine is supplied with and config-
ured for this option.
0
Third water valve off
1
Third water valve on
2
Raises temperature of filling water if connected to a hot water
source
3
Lowers temperature of filling water if connected to a cold water
source
If a temperature is programmed in a step, the control requires either modulated water (H=2 and
C=1 or 3, or C=3 and H=1 or 2) or steam injection, otherwise the cursor returns to the tempera-
ture decision for correction. See
2.3.3.6.2.1: How to Modulate Water Valves to Regulate Incom-
ing Water Temperature, page 29
for details on how to regulate the temperature of incoming water.
Summary of Contents for E-P Plus
Page 2: ......