Pellerin Milnor Corporation
65
Table 13.
E-P Plus Outputs
Output
Number
Page-
Column
Description
Device
Consequences of Actuation
1
0–a
Inject chemical 5
K1
Operates inject device for chemical 5
2
0–b
Inject chemical 1
K2
Operates inject device for chemical 1
3
0–c
Inject chemical 4
K3
Operates inject device for chemical 4
4
0–d
Inject chemical 3
K4
Operates inject device for chemical 3
5
0–e
Inject chemical 2
K5
Operates inject device for chemical 2
6
0–f
Hot water valve
K6
Opens valve
7
0–g
Cold water valve
K7
Opens valve
8
0–h
Drain solenoid
K8
Closes drain
9
0–i
Flush valve
K9
Opens flush valve
10
0–j
Cooldown (if equipped)
K10
Operates cooldown valve, if equipped
11
0–k
Extra water (if
equipped)
K11
Operates extra water valve, if equipped
12
1–a
Reuse drain (if
equipped)
K12
Operates reuse drain, if equipped
13
1–b
Steam (if equipped)
K13
Operates steam valve, if equipped
14
1–c
Inject chemical 6
K14
Operates inject device for chemical 6
15
1–d
not used
K15
16
1–e
Door interlock
K16
Energizes door latch to locked position
17
1–f
Unlock door
K17
Energizes door latch to unlocked position
18
1–g
Wash clutch
K18
Engages wash clutch
19
1–h
Extract speed (use only
with empty cylinder)
K19
Locks door, releases brake (if any), and turns
cylinder at extract speed.
20
1–i
Distribution (drain)
speed (Door must be
closed)
K20
Locks door, releases brake (if any), and turns
cylinder at drain speed.
21
1–j
Clockwise wash speed
(Door must be closed)
K21
Locks door, releases brake (if any), and turns
cylinder clockwise at wash speed.
22
1–k
Counter-clockwise wash
speed (Door must be
closed)
K22
Locks door, releases brake (if any), and turns
cylinder counter-clockwise at wash speed.
23
Buzz signal
Board-mounted
signal
Sounds operator alarm
24
Run light
Board-mounted
light
Turns on light in Start button (\)
25
Reversing wash speed
Functional test
Locks door and reverses cylinder at wash
speed.
26
High Speed extract
Functional test
Locks door and `turns cylinder clockwise at
wash speed, then high extract speed.
27
Fill to level 1
Functional test
Locks door, closes drain, fills to level 1 with
cold water.
28
Fill to level 2
Functional test
Locks door, closes drain, fills to level 2 with
cold water.
Summary of Contents for E-P Plus
Page 2: ......