Pellerin Milnor Corporation
13
An inherent risk of this method of chemical injection is that concentrated chemicals can dribble
into the machine after it is shut down for the evening, causing machine and/or linen damage. Be-
cause Milnor
®
has no control over the design or installation of pumped chemical systems, Pellerin
Milnor Corporation accepts absolutely no responsibility for damage to its equipment or textiles
therein caused in this way. Much more information on this subject is provided in
Damage from Chemical Supplies and Chemical Systems, page 7
. Consult this document before
connecting a pumped chemical system.
1.5.4
Connecting Devices to Receive Injection Signals
BNCJVI01.R04 0000181445 C.2 D.5 B.3 1/2/20 1:16 PM Released
For 36-inch and 42-inch V_J models, injection signals provide either 110VAC/50Hz or 120VAC/
60Hz potential. For 30-inch V_J and all F_J/F_B, H_J, and X_J models, injection signals provide
either 220VAC/50Hz or 240VAC/60Hz potential. Each signal can accomodate one apparatus not
exceeding 37 milliamperes. Inject signals cannot be made potential-free.
CAUTION:
Avoid Component Damage —
Board components will burn out and re-
quire board replacement if devices driven by inject signals do not meet the
electrical specifications. Pumps generally draw a higher current and will
burn out board components.
1.5.5
Connecting Chemicals to H_J, X_J, and 30-inch V_J
Models
BNCJVI01.R05 0000181444 C.2 D.5 B.3 1/2/20 1:16 PM Released
Acquire signals at connector TBS near the rear access panel, next to the incoming power connec-
tions. See the following table for connection details.
Table 3.
Chemical Injection Signals for H_J, X_J, and 30-inch V_J Models
Signal
Component
Chemical
Relay
Processor Board
Connection
Terminal
Number
Chemical 1
Detergent
CR01M
M5-3
95
Chemical 2
Bleach
CR02M
M5-6
93
Chemical 3
Sour
CR03M
M5-5
91
Chemical 4
Softener
CR04M
M5-4
75
*Chemical 5
Starch
CR05M
M5-2
85
**Chemical 6
—
CR06M
M3-10
Common
all
—
—
6
* Chemical 5 is not used if the machine is equipped and configured for ChemSave. In this case,
relay CR05M closes whenever the machine desires to inject a chemical.
** Chemical 6 is available only on H_J and X_J models with version software WUH7JA/2200N
or later.