72
Pellerin Milnor Corporation
displays the last 11 outputs (Page 1).
PAGE abcdefghijk
0
-+----+----
typical display of first page of outputs (Page 0) while the machine
is running. Refer to
Table 13: E-P Plus Outputs, page 65
to deter-
mine the component represented by each character on Page 0 and
Page 1.
4.1.8
Viewing Water Level and Temperature Data During
Operation
BNCJHT01.R07 0000191876 C.2 F.3 C.3 1/2/20 1:16 PM Released
Display or Action
Explanation
displays pressure transducer raw data and actual water level in
tenths
03:45 STEP #01 05:36
08240 081 080
LEV 2
From left to right, the bottom line displays the pressure transducer
raw data, the actual water level and the filtered water level in
tenths, and the desired level.
displays the calculated level, the desired level, and the
temperature
03:48 STEP #01 05:36
LC07/LD07/T103 LEV 2
From left to right, the bottom line displays the calculate water lev-
el, the desired water level, and the water temperature. The level
values on this display take into account any configured
offset
height
(see
2.3.4.2: The Configure Decisions, page 41
BNCJHT02 / 2018385
BNCJHT02
0000192158
B.3
1/2/20 1:16 PM
Released
4.2
Error Messages
BNCJHT02.C01 0000192157 C.2 B.3 A.8 1/2/20 1:16 PM Released
4.2.1
Error Messages at Power Up
BNCJHT02.T01 0000192156 C.2 B.3 A.8 1/2/20 1:16 PM Released
If an error message appears during power up, the error must be cleared before the machine can be
run or programmed.
Display or Action
Explanation
ACCUMULATOR ERROR
The microprocessor performs a memory check each time the ma-
chine is turned on. This error message appears if the microproces-
sor detects that the accumulator data is corrupt, in which case all
accumulators must be reset to zero.
TERMINATE TO CLEAR
Resets all accumulators and clears the error message. See
How to Use and Erase the Formula Counter, page 60
for more
information.
CHECKSUM ERROR,TURN
Appears if there is illegal data in the configuration, formula, or in-
dustry memory areas. Use the following procedure to clear this
error.
KEY TO PROGRAM
Summary of Contents for E-P Plus
Page 2: ......