Enhancement Param.
P845
Long Shot Width
Use this feature to adjust the width (in ms) of the long shot transmit pulse.
This feature is automatically adjusted by Transducer (P004).
Values:
0.000 to 5.000
P850
Short Shot Bias
Use this feature to slant the echo evaluation in favour of the short shot echo when
both short and long shots are evaluated (see Shot Mode, P803). This feature is
preset to 20.
Values:
0 to 100
P851
Short Shot Floor
Enter the minimum echo strength (in dB above 1
µ
V rms), initiated from a short shot,
to be considered for evaluation. This feature is preset to 50.
Values:
0 to 100
P852
Short Shot Range
Enter the maximum distance in Units (P005) to be measured using short shot
echoes.
This feature is automatically altered when Transducer (P004) is altered.
Values:
0.000 to 9999