Scanning Parameters (P725 to P729)
P726
Level System Sync
Use this feature if another level measurement system is mounted near the SPL.
See Installation Interconnection / Level System Synchronization.
Values:
0 = not required
1 = synchronize level monitors (preset)
P728
Shot Delay
Use this feature if transient acoustic noise within the vessel is causing measurement
difficulties.
This value is automatically altered when Measurement Response (P003) is altered.
(See Technical Reference / Measurement Response.)
Enter the delay between transmit pulse shots (in seconds).
Values:
0.1 to 4.0
P729 (V)
Scan Time
View the time elapsed (in seconds) since the point displayed was last scanned. This
value may be viewed as an Auxiliary Reading in the Run mode. See Operation /
Keypad.
Values:
0.000 to 9999