PL-573
AiRanger SPL
Page 5
Specifications
Specifications
Electronics
Power:
ac:
100/115/200/230 V ac
±
15%, 50/60 Hz, 31 VA
Environmental:
location
indoor / outdoor
altitude
2000 m max
ambient temperature
–20 to 50°C (–5 to 122 °F)
relative humidity
suitable for outdoor (Type 4X / NEMA 4X / IP65
enclosure)
installation category
II
pollution degree:
4
Scan Points:
1 point per AiRanger SPL max.
frequency independent
Range:
Level Measurement:
0.3 m (1 ft) to 60 m (200 ft) max.
Accuracy:
0.25% of range or 6 mm (0.24"), whichever is greater
Resolution:
0.1% of program range
*
or 2 mm (0.08"), whichever is greater
Memory:
EEPROM (non-volatile) no back-up battery required
Programming:
via removable programmer or optional Dolphin Plus
Display:
Custom Graphics backlit LCD with 51 mm (2 in) x 127 mm (5 in) viewing
area
Temperature Compensation:
–50 to 150 °C (–58 to 302 °F)
integral transducer sensor
TS-3 temperature sensor
programmable fixed temperature
Temperature Error:
with compensation:
0.09% of range
fixed temperature:
0.17% / °C deviation from programmed temperature.
Outputs:
transducer drive:
150 to 315 V peak (transducer model dependent)
relays:
4 alarm/control relays
1 form "C" SPDT contact per relay,
rated 5 A at 250 V ac, non-inductive
analog:
1 output max.
0.1% resolution
0-20 or 4-20 mA, scalable
750
Ω
, isolated, 30V rms
*
program range is defined as the empty distance to the face of the transducer
(P006) plus any range extension (P801).
Summary of Contents for AiRanger SPL PL-573
Page 1: ...AIRANGER SPL Instruction Manual PL 573 March 2001 IRANGER SPL 33455730 Rev 1 2 ...
Page 8: ...Page 8 AiRanger SPL PL 573 Specifications ...
Page 24: ...Page 24 AiRanger SPL PL 573 Installation ...
Page 86: ...Page 86 AiRanger SPL PL 573 Enhancement Param ...
Page 102: ...Page 102 AiRanger SPL PL 573 Maintenance ...
Page 108: ...Page 108 AiRanger SPL PL 573 Troubleshooting ...