SmartTime Static Timing Analyzer User Guide
129
Parameter/Value
Description
-from_clock <clock
name>
Reports only bottleneck instances that lie on violating timing
paths of the inter-clock domain that starts at the source clock
specified by this option. This option can only be used in
combination with -to_clock.
-to_clock <clock name> Reports only instances that lie on violating paths that end at
locations specified by this option.
-in_to_out
Reports only instances that lie on violating paths that begin at
input ports and end at output ports.
Example
The following example generates a timing violation report named timing_viol.txt. The report considers an
analysis using maximimum delays and does not filter paths based on slack threshold. It reports two paths
per section and one expanded path per section.
report –type timing_violations \
-analysis max –use_slack_threshold no \
-limit_max_paths –yes \
-max_paths 2 \
-max_expanded_paths 1\
timing_viol.txt