5-18
Workstation 4 and 4 LX Field Service Guide
WS4 LX Troubleshooting
Mechanical Related
Mechanical Related
Power Button Sticks
Symptoms: The Power button actuator is recessed and the WS4 LX does not change
states when pressed.
•
Damaged Power Button Actuator.
The plastic actuator is heat staked to the base but can be damaged by excessive
force. If this occurs, the workstation base must be replaced.
•
Power Switch Alignment.
There are two possible causes for this.
•
Loose or missing system board mounting screws. In particular, the three front
mounted stand-off’s. All system board hardware should be installed and
secured.
•
The system board power switch is mis-aligned. This occurs in very rare cases.
Removal and re-mounting of the system board switch may improve the
situation.