32 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 33
Operating mode 3: INPUT
The values of various parameters can be changed in INPUT
mode.
Display:
− Displays the selected parameter
− Displays the status/value set
Operating mode 4: DIAGNOSIS
Door-specific checks can be interrogated in DIAGNOSIS mode.
Display:
− Display of the check
− Display of the check status
8.3
8.3 Expert menu
Expert menu
Under factory settings (standard), only a few parameters
appear in the INPUT operating mode, which can be adjusted
by the operator. These setting parameters reflect the most
frequently applied requirements for an industrial door system
and are sufficient for commissioning in a standard situation.
The last item in this list is the “EXPERT MENU” parameter.
This is always set to OFF.
OFF: Limited number of parameter settings:
− Menu language
− INT POS UP
− OPEN TIME
− FOREWARNING TIME
− FAST CLOSE
− REVERSE OFF
− INPUT 1
− SELF LOCK
− BRAKE P OP
− BRAKE P CL
− SPEED OPEN
− SPEED CLOSE
− SOFTRUN OP.
− SOFTRUN CL.
− SPEED UP OP.
− SPEED UP CL.
− SLO. DO. OP.
− SLO. DO. CL.
− MOTOR V
− MOTOR I
− MOTOR P
− MOTOR PHI
− MOTOR HZ
− MOTOR RPM
− EXPERT MENU
Setting the EXPERT MENU parameter to ON activates the
expert mode. It is now possible to call up and set all input
menu parameters.
➔
Note
− The expert mode is automatically exited after approx.
7 minutes, if no button is pressed. Now, only the limited
selection of parameters is once again available until the
EXPERT MENU parameter is set to ON again.
− The same applies to switching off the power. This once
again sets the EXPERT MENU parameter to OFF.
8.4
8.4 RESET
RESET
The RESET function can be used to reset the control
parameters to the pre-selected factory settings.
➔
FACTORY SETTING parameter
Selection of the parameter set that should be reset with a
RESET.
It is possible to implement different types of reset whereby
more or less settings are reset.
➔
RESET parameter
Part reset 1 :
All parameter settings are reset, apart from the settings for
the frequency converter (only with CS 320 FU).
Part reset 2 :
All parameter settings are reset, apart from the settings for
the limit positions and the detected limit position system.
Full reset :
Everything is reset to factory settings.
➔
„8.5 RESETTING the controller with LCD monitor“
➔
„8.6 RESETTING the controller without LCD monitor“
Programming