26 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 27
EN
5.20
5.20 Connection of LCD monitor
Connection of LCD monitor
Full access to all menu settings and parameters of the
controller is possible via the LCD monitor.
➔
Plug-in base X8
5.20 / 1
ATTENTION!
Property damage due to improper installation!
The LCD monitor must be plugged in whilst de-energised.
Only an LCD monitor from MFZ (art. no. 91447) may be
used.
ATTENTION!
Property damage due to improper installation!
The MFZ LED module (art. no. 103239) cannot be combined
with the CS 320 FU. Use and commissioning can lead to
destruction of the CS 320 FU circuit board.
5.20 / 2
5.21
5.21 Connection of MS BUS components
Connection of MS BUS components
Two BUS interfaces are present on the circuit board for
connecting different components.
The MS-BUS LCD monitor (#121246) is supplied with a 3 m
long connection cable.
The MS-Bus LCD monitor (like the standard LCD monitor)
permits full access to all parameter settings.
It is possible to expand functions or realise additional
functions with the MS BUS function modules.
− ES module:
Evaluation of trap-in protection
systems
− I/O module:
Input/output expansion
− GV module:
Two-way control
Connector strip X16 / X17
B
A
5.21 / 1
A
ES module
Connection to X16 or X17
B
I/O module / GV module Connection to X16 or X17
C
LCD monitor
Connection to X16 only
REFERENCE
For a precise description of the function and connection,
refer to the separate documentation for the BUS modules.
NOTE:
The connector strips X16 and X17 can only be assigned once.
However, multiple BUS modules can be connected through
special bypass cables.
The current consumption must be considered with this.