EN
Control CS 320 FU / Rev.A 1.01 – 45
Function
Description
Adjustment
options
Factory setting
INPUT 1
Selection of a function that should be assigned to input 1 (X4 / 9+10).
MOD1:
Button Sect. UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD2:
Switch Sect. UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD3:
Switch auto CL.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD4:
External CLOCK (permanent UP) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD5:
Switch BMA 3 (Sect. opening) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD6:
Switch BMA 1 (emergency closing) . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD7:
Switch BMA 1 (emergency closing) . . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD8:
Switch BMA 2 (emergency opening) . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD9:
Switch BMA 2 (emergency opening) . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD10: Button ventilation function (Sect. opening) . . . . . . . . . . . . . . . . . . . .
NO
MOD11: Button automatic closing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD12:
Laser scanner (height detection) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD13: Switch BMA 3 (Sect. opening) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD14: Slip door locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD15: Light barrier 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD16: Forewarning switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD17: Impuls button
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD18: Crash sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD19: Lock operation commands via LCD monitor . . . . . . . . . . . . . . . . . . .
NC
MOD22: Monitoring an external load contactor . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD30:
UP switch inside . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD31:
UP switch outside . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD32:
DOWN switch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
(only active with functioning closing edge protective device and
functioning light barrier 1. No function in dead-man’s operation.)
MOD1 – MOD19
MOD22
MOD30 – MOD32
MOD1
INPUT 2
Selection of a function that should be assigned to input 2 (X4 / 11+12).
OFF:
NOT active
MOD2:
Slip door switch - STOP with deviation . . . . . . . . . . . . . . . . . . . . .
8.2 kΩ
MOD3:
Switching strip – active in UP direction . . . . . . . . . . . . . . . . . . .
8.2 kΩ
Stops and reverses with actuation
MOD4:
Switching strip – active in UP direction . . . . . . . . . . . . . . . . . . .
8.2 kΩ
Stop and rev with actuation
MOD5:
Battery operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NO
MOD6:
Radar movement detector (height detection) . . . . . . . . . . . . . . . . . . .
NO
MOD7:
Light grid 2 (SSR / PNP) with testing . . . . . . . . . . . . . . . . . . . . . . . . .
NC
MOD8:
Safety switching with resistance evaluation . . . . . . . . . . . . . . . . . .
xx Ω
MOD9:
Safety element - STOP with deviation . . . . . . . . . . . . . . . . . . . . . . .
OSE
MOD10:
Switching strip – active in UP direction . . . . . . . . . . . . . . . . . . . . . .
OSE
Stops and reverses with actuation
MOD11:
Switching strip – active in UP direction . . . . . . . . . . . . . . . . . . . . . .
OSE
Stop and rev (2 sec.) with actuation
MOD12:
Light grid 2 without testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OSE
With first commissioning and after a reset, input 2 is set to A - self-teaching once. If
a resistance value is detected, MOD8 (safety input 5.14) is automatically set and the
measured value is stored and monitored as a reference for the connected safety-
related components.
A single switching strip 8.2 kOhm (MOD 3/4) must be manually activated.
If no connected component is detected during initial commissioning or after a reset,
the input is automatically deactivated. OFF appears in the display and the input must
be manually activated.
A (teaching)
OFF
MOD2 – MOD12
A