30 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 31
7.4
7.4 Setting the electronic limit position
Setting the electronic limit position
system via the LCD monitor
system via the LCD monitor
ATTENTION!
Improper assembly will cause damage or
destruction!
The monitor must be plugged in whilst de-energised. Only a
standard LCD monitor (#91447) from MFZ may be used.
Change to adjustment mode
Press the (P) button until ADJUSTMENT appears.
Setting the UP end position
Drive the door to the desired UP end position by pressing
the (+/–) buttons.
Save end positions by pressing the (P) button and
additionally also the (+) button.
“STORE UP” appears in the display.
Setting the DOWN end position
Drive the door to the desired DOWN end position with the
(+/–) buttons.
Save end position by pressing the (P) button and additionally
also the (–) button.
“STORE DOWN” appears in the display.
The adjustment mode is automatically exited.
Note
− The adjustment mode is automatically exited after approx.
7 minutes, if no button is pressed.
− Normal operation is not possible until both end positions
have been learned through the initial calibration.
− If an end position is to be corrected, the ADJUSTMENT
mode can be exited by pressing the (P) button after
learning the special end positions.
− After programming the limit switches, the system run-time
is learned automatically. The display shows TEACH IN RUN.
The controller functions are the same as in automatic mode.
7.5
7.5 Setting the intermediate positions of the
Setting the intermediate positions of the
electronic limit position system via the
electronic limit position system via the
LCD monitor
LCD monitor
Drive the door to the desired position in automatic
mode
Drive the door to the desired intermediate positions
(INT POS UP or INT POS DOWN) with the (+/–) buttons.
Change to input mode
Press the (P) button until INPUT appears.
Press and hold the buttons (+) and (–) simultaneously for
more than 2 seconds. The first parameter appears in the
second line of the display.
Save the intermediate UP (INT POS UP) or DOWN
(INT POS DOWN) position
Press the buttons (+/–) until the parameter INT POS UP or
INT POS DOWN appears.
The value stands at A.
Press the button (P) to accept the current door position as
the intermediate position.
Save the intermediate position by pressing the (P) button
again.
Exit Input operating mode
Press and hold the buttons (+) and (–) simultaneously for
more than 1 second.
Input is exited.
Change to automatic mode
Press the (P) button until AUTOMATIC appears.
Note
If an intermediate position is to be corrected, the taught value
can be changed in the INPUT menu or set to A again, so that
a new teach-in can be started.
Setting the limit positions