54 – Control CS 320 FU / Rev.A 1.01
H.
Input-dependent messages
MOD
Description
Remarks
MOD32
Battery operation
Active with battery operation. Input 2 is bridged (setting MOD5).
MOD33
no battery operation
Active with mains operation. Input 2 is open (setting MOD5).
When programmed with MOD32/33, the relays operate as delayed changeover contacts and follow the
signal at input 2 when MOD5 is set.
In this case, input 2 is fed with a control signal from the UPS system, which ensures the changeover
between mains supply and UPS supply.
MOD34
BMA signal
Switches with an active fire alarm system.
Follows the signal at input 1 with setting MOD5-9 / 13.
In this case, input 1 is fed with a control signal from the fire alarm system and, depending on the setting,
the door opens or closes to an end or intermediate position.
I.
System messages
MOD
Description
Remarks
MOD31
Service
The relay is active after reaching the programmed service interval. Only after the service interval is reset or
redefined does the relay drop out again.
➔
„10.2 Input operating mode“ on page 35
MOD46
ADJUSTMENT operating mode
The relay is active if the control is in the ADJUSTMENT operating mode.
11.4
11.4 Explanations of the inputs:
Explanations of the inputs:
A.
Functions input 1
MOD
Description
Remarks
MOD1
SECT. OPEN button
By pressing the button (input 1), the door opens to the intermediate OPEN position (SECT. OPEN).
MOD2
SECT. OPEN switch
Closed:
All OPEN commands lead to intermediate OPEN position (SECT. OPEN).
Open:
All OPEN commands lead to the OPEN limit position.
MOD3
AUT.CLOSE switch
Closed:
No automatic closing.
(Open time stops, if open time > 0).
Open:
Automatic closing is active (if open time > 0).
MOD4
External CLOCK (permanent OPEN)
The door opens as soon as the contact closes and remains in the OPEN position (maintain open time)
until the contact opens. Then the door drives closed automatically (only with open time > 0). This function
can be cancelled by actuating the CLOSE button. The door drives CLOSED.
Functional overviews