5.8 Connection of command devices
CAUTION!
Risk of injury due to uncontrolled door movement!
A CLOSE command in dead-man operation without a view
of the door is not permitted.
Install the command devices for the dead-man operation
Install the command devices for the dead-man operation
in direct visual contact with the door, although outside
in direct visual contact with the door, although outside
the danger zone for the operator.
the danger zone for the operator.
A CLOSE command without visual sight of the door may
only be given via input 1 / MOD32 (X4 / 9-10).
If the command device is not a key switch:
Install it at a height of at least 1.5 m.
Install it at a height of at least 1.5 m.
Install it where it is inaccessible to the public.
Install it where it is inaccessible to the public.
Command devices (standard)
X3
A
B
C
D
E
5.8 / 1
Legend:
A
Button / input DOWN
B
Button / input impuls
C
Button / input UP
(UP inside, with active two-way control)
D
STOP button
E
Emergency stop command device
UP / STOP / DOWN switch (6-wire solution)
X3
A
C
D
5.8 / 2
UP / STOP / DOWN switch (4-wire solution)
X3
A
C
D
5.8 / 3
IMPULS button
Selection of the function via IMPULS parameter
➔
„11.2 Input operating mode“ on page 41
B
X3
5.8 / 4
- UP switch
- STOP button