12 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 13
5.5
5.5 Supply to external devices
Supply to external devices
(only with 400 V / 3-phase connection)
(only with 400 V / 3-phase connection)
The CS 320 FU has 2 separate voltage supplies for external
components, such as signal devices, light barriers, etc.
X19 230V/1~
X4
24V-DC
N
L3
L2
L1
X1
X21
X19
3
400 V / 50 Hz
max. 1A
230V-AC
max. 500mA
24V-DC
/ N / PE
X4
1
2
3
4
5
6
7
8
9
12
11
10
F1
-
+
L
N
5.5 / 1
NOTE:
Use of the connection X19 is only possible with a supply with
400V / N / 3~.
The connection X19 is protected by the fuse element F1
(max. 1 A / T).
5.6
5.6 Connection of electronic limit position
Connection of electronic limit position
system absolute value encoder (AWG)
system absolute value encoder (AWG)
5.6 / 1
A
B
A:
Absolute value encoder plug
B:
AWG plug-in terminal
Connector strip X11 (on connector A)
4 7
grey
yellow
5 8
green
pink
6 9
white
brown
5.6 / 2
Cables with either numbered or
coloured wires are used for the AWG,
depending on the drive:
4 (grey): Safety chain input
5 (green): RS 485 B
6 (white): GND
7 (yellow): RS485 A
8 (pink): Safety circuit output
9 (brown): 12V DC
Connector strip B (only absolute value encoder)
5.6 / 3
C:
Thermal element in the drive
D:
Emergency manual actuation (emergency crank or
emergency chain)
Installation