Service functions and error messages
Page 138
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
03
0
Overtemperature analogue
motor
Motor too hot? Check the parameterization
(current controller, current limitation).
Suitable sensor?
Sensor defective?
Check the parameterization of the sensor or the
sensor characteristic curve.
Error also occurs if sensor is bypassed: device
defective. Please, send the servo drive to our
sales partner.
1
Overtemperature digital motor
2
Overtemperature motor
analogue: Wire break
Check cables of temperature sensor (broken
wire).
Check the parameterization of wire break
monitoring (threshold value).
3
Overtemperature motor
analogue: Short circuit
Check cables of temperature sensor (short
circuit).
Check the parameterization of short circuit
monitoring (threshold value).
04
0
Overtemperature of the power
stage
Plausible temperature display?
Check the installation conditions, filter mats of
fan dirty?
Device fan defective?
1
Overtemperature in the DC-bus
05
0
Internal undervoltage supply 1
Disconnect the device from the entire periphery
and check whether the error persists after a
reset.
If the error persists, please send the servo drive
to our sales partner.
1
Internal undervoltage supply 2
2
Driver voltage failure
3
Undervoltage dig. I/O
Check the outputs for short-circuits or specific
load. If necessary, contact the Technical
Support.
4
Overcurrent dig. I/O
06
0
Short circuit in the power stage Motor defective?
Short-circuit in cable?
Power stage defective?
1
Overcurrent brake chopper
Check the external brake resistor: Short circuit or
resistance value too low?
Check braking chopper output of the device.
Summary of Contents for ARS 2320