Technology modules
Page 157
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
11.2
PROFIBUS-DP interface
11.2.1
Product description
The PROFIBUS-DP interface provides an additional field bus connection. All functions and parameters
can be addressed directly, for example from a Simatic S7 control system. The interface is plugged into
the technology slot TECH 2 of the ARS 2300 servo drive.
The PROFIBUS-DP interface is supported solely in the
TECH 2
technology slot.
In addition to the PROFIBUS-DP interface, the TECH 1 technology slot can also be used
for the I/O extension module EA88.
Additional technology modules will not be supported if the PROFIBUS-DP interface is
used.
If your specific requirements are more complex, please contact your sales partner in
order to find a solution for your particular application.
As a special feature, S7 function blocks have been developed for the servo drives. Using these
function blocks, the servo drives can be controlled directly by the PLC program and the users can
integrate their systems easily and clearly into the Simatic S7 environment.
11.2.2
Technical data
Table 53:
Technical data: PROFIBUS-DP interface: Ambient conditions, dimensions and
weight
Range
Values
Storage temperature range
-25 °C to +75°C
Operating temperature range /
deratings
0°C to 50°C
Atmospheric humidity
0..90%, non-condensing
Altitude
Up to 2000 m above msl
External dimensions (LxWxH):
approx. 92 x 65 x 19mm
suitable for the technology slot TECH 2
Weight:
approx. 50g