Error message Meaning of the error message Measures
Main
index
Sub
index
07
0
Overvoltage in the DC-bus
Check connection to braking resistor (internal /
external).
External braking resistor overloaded?
Check rating.
08
0
Angle encoder error resolver
See measures 08-2 .. 08-8.
1
Sense of rotation of the serial
and incremental position
evaluation is not identical
A and B-track are mixed up?
Correct (check) the connection of the tracks.
2
Error of track signals Z0
Incremental encoder
Angle encoder connected?
Angle encoder cable defective?
Angle encoder defective?
Check the configuration of the angle encoder
interface.
The encoder signals are disturbed: check the
installation for compliance with EMC
recommendations
3
Error of track signals Z1
Incremental encoder
4
Error of track signals of digital
incremental encoder
5
Error of Hall signals incremental
encoder
6
Communication error encoder
7
Signal amplitude incremental
track erroneous
8
Internal encoder error
Internal monitoring of the angle encoder at [X2B]
has identified an error.
Communication error?
Check the encoder type, contact the Technical
Support if necessary.
9
Encoder at X2B not supported
Please contact the Technical Support
09
0
Old encoder parameter set
(type ARS)
Save data into the encoder EEPROM (new
format)
1
Encoder parameter set cannot
be decoded
Encoder defect?
Check encoder interface configuration.
The encoder signals are disturbed.
Check the installation for compliance with EMC
recommendations
2
Unknown encoder parameter
set version
Save the data into the encoder again.