Technical data
Page 46
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
4.4.2
I
2
xt derating for ARS 2320W and ARS 2360W
For these two servo drives it is necessary to calculate a derating for the duration of the maximum
current as a function of the pulse frequency (f
PWM
) and the electrical rotational frequency in the
firmware. The following figure shows the 4 essential set points.
IIT(
f
el,
f
pwm) /
[s]
f
el /
[Hz]
1
2
3
4
f
pwm /
[kHz]
0,2
1
2
3
1
2
3
4
5
6
5
15
Figure 6:
ARS 23xxW: I
2
xt derating diagram
Table 14:
I
2
xt – times (set points 1 to 4)
Set points*
1
2
3
4
f
el
/ Hz
up to 1 Hz
as of 3 Hz
up to 2 Hz
as of 6 Hz
F
PWM
/ kHz
5
5
15
15
I
max
/ A (ARS 2320W)
50
50
45
45
I
max
/ A (ARS 2360W)
120
120
90
90
I
2
xt / s
0,2
3
0,2
3
* Linearization between the single set points.