Electrical installation
Page 110
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
8.8
Connection: Safe Torque Off (STO) [X3]
For the description of the safety function “Safe Torque-Off (STO)”, please refer to
chapter 6.2
Integrated “Safe torque-Off (STO)” function
.
8.8.1
Configuration on the device [X3]
PHOENIX Mini-Combicon MC 1,5/6-STF-3,81
8.8.2
Counter plug [X3]
PHOENIX Mini-Combicon MC 1,5/ 6-GF-3,81
8.8.3
Pin assignment [X3]
Table 36:
Pin assignment: [X3]
Pin No
Name
Values
Specification
1
24V
24VDC
24VDC supply led out
(Without the safety function: Bridge pin 1 and 2)
2
REL
0V / 24VDC
Setting and resetting of the relay for interrupting the driver
supply
3
0V
0V
Reference potential for the PLC
4
ERR
0V / 24VDC
Signalling contact “Error on safety module”
5
NC1
250VAC max.
switching
voltage
Floating response contact of driver supply;
normally closed contact
6
NC2