Service functions and error messages
Page 150
Product Manual „Servo drives ARS 2320, ARS 2340, ARS 2320W, ARS 2360W“
Version 8.0
Error message Meaning of the error message Measures
Main
index
Sub
index
50
0
CAN:
Too many synchronous PDOs
Deactivate the PDOs or increase the SYNC
interval. The maximum number of PDOs must
not be greater than the factor tp between the
position controller and IPO (menu:
Parameters/Controller parameters/Cycle times)
1
SDO error occurred
Please contact the Technical Support.
60
0
Ethernet user-specific (1)
Please contact the Technical Support.
61
0
Ethernet user-specific (2)
Please contact the Technical Support.
62
0
EtherCAT: General bus error
No EtherCAT bus available.
Check the cabling.
1
EtherCAT: Initialization error
Replace the technology module.
If necessary, contact the Technical Support.
2
EtherCAT: Protocol error
Wrong protocol (no CAN over EtherCAT)?
Check the EtherCAT wiring.
3
EtherCAT: Invalid RPDO length Check the protocol.
Check the RPDO configuration of the servo drive
and of the control system.
4
EtherCAT: Invalid TPDO length
5
EtherCAT: Erroneous cyclic
communication
Check the EtherCAT wiring.
Check the configuration of the master system.
63
0
EtherCAT: Defective module
Technology module defective?
Replace the technology module.
1
EtherCAT: Invalid data
Check the protocol.
Check the EtherCAT wiring.
2
EtherCAT:
TPDO data has not been read
Reduce the cycle time (EtherCAT bus).
3
EtherCAT:
No distributed clocks active
Check whether the master supports the
“distributed clocks” feature.
If necessary, contact the Technical Support.
4
Missing SYNC message in IPO
cycle
Check the cycle times of the servo drive and of
the control system.
64
0
DeviceNet: Duplicate MAC ID
Change the MAC ID.
1
DeviceNet: Bus power lost
Check the DeviceNet wiring.
Summary of Contents for ARS 2320