Section 5 - Maintenance
90-899883154 JANUARY 2008
Page 103
5. Pull lever on air pump (vertical) to lock pump on the fitting.
8293
b
d
e
a
c
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve
d -
Air pump
e -
Lever (locking)
6. Pump air into the system until both green indicators extend and water drains from both
sides of the engine. The port side will begin draining before the starboard side.
b
c
a
8294
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve