- 32 -
6-4. SPEC INITIALIZE1 Command
COMMAND………
01
Function : Defines operation specifications.
H
Execution sequence
Drive control specifications are defined in DRIVE DATA1.
N
BUSY=0 in
STATUS1?
The contents of DRIVE DATA1 PORT is as follows.
Y
DATA1 PORT
7
0
DATA1 PORT
D
D
WRITE
COMMAND 01
DRIVE TYPE
H
WRITE
LIMIT STOP TYPE
MOTOR TYPE
RDYINT TYPE
The bit marked slash may be set to 0 or 1.
The details of each bit are shown below.
The bit is set to the underlined side at POWER ON/RESET.
(1) DRIVE TYPE (D ,D )
1
0
Specifies DRIVE TYPE.
D
D
DRIVE TYPE
1
0
0
0
L-TYPE
0
1
M-TYPE
1
0
H-TYPE
Note: For the arithmetic mode, refer to
1
1
Arithmetic mode (Note)
the User's Manual [Applied Functions Part].
(2) LIMIT STOP TYPE (D )
2
Specifies the type of LIMIT STOP by the CWLM and CCWLM signals.
0: Fast stop
1: Slow stop
(3) MOTOR TYPE (D )
3
Specifies the target motor.
0: SERVO
1: STEPPING
(4) RDYINT TYPE (D ,D )
5
4
Specifies an interrupt request (RDYINT) generation pattern upon termination of a command.
D
D
Generation pattern
5
4
0
0 Generated upon termination of a command accompanied by pulse output.
0
1 Generated upon termination of every command.
1
x Not output in any case.
Summary of Contents for C-875